Secured Trading Service

Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter

Yueqing Page Electrical Co., Ltd.
  • Audited Supplier
  • 11 yrs

Contact Supplier

Still deciding? Get samples of $ !
Order Sample

Product Highlights

  • 24-Month Warranty: Comprehensive 24-month warranty coverage for all mechanical and electrical defects.
  • 24-Hour After-Sales Support: Round-the-clock technical assistance available for troubleshooting and maintenance.
  • RoHS, ISO, CE Certified: Meets international safety and environmental standards including RoHS, ISO, and CE.
  • Wide Voltage Range: Operates on 110V/127V/133V or 230V/240V AC with -15% to +10% tolerance.
  • High Current Capacity: Rated current 5A with maximum rated current up to 45A for heavy loads.
  • Long Data Storage: Stores measurement data for over 25 years even without power supply.
  • OEM Branding Available: Customize with your own brand name and model number for private labeling.
  • DIN Rail Mounting: Standard DIN 35mm rail installation for easy integration into electrical panels.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter

Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter pictures & photos
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter pictures & photos
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter pictures & photos
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter pictures & photos
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter pictures & photos
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter pictures & photos
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
    Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
    Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
    Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
    Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
    Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
  • Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
    Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter

Find Similar Products

Product Description

Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Specification
Meter type
ZM18SC (LCD display)
Digit length
5+2/6+1
Nominal voltage(Un)
110V/127V/133V AC
230/240V AC(option)
Operational voltage
(-15% ~ +10%)Un
Insulation capabilities
- AC voltage withstand
2KV for 1 minute
- Impulse voltage withstand
6KV – 1.2µS waveform
Rated current (Ib)
5A
Maximum rated current (Imax)
45A
Operational current range
0.4% Ib- Imax
Over current withstand
30Imax for 0.01s
Operational frequency range
50/60Hz ±10%
Internal power consumption
≤2W / 10VA
Test output flash rate (RED LED)
1000/2000imp/kWh
Pulse output rate (pins 20 & 21)
1000/2000imp/kWh
Consumption indicator (RED LED)
Flashing at load running
Data store
The data can be stored for more than 25 years without power
Packing & Delivery
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Product Description
This single phase DIN rail KWH meter features 1 module compact design for 220V/230V 50/60Hz systems. Available in 5(20)A-5(100)A ranges, Class 1.0 high accuracy with pulse output. CE certified and IEC62053-21 compliant. Easy to mount on standard DIN rail, ideal for residential and commercial electricity metering.
Company Profile
Company Name
PAGELE CO., LTD
provides series of Single phase, Three phases meters design, engineering, and full after sales support for a wide range of Electrical_System_Control applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
Single Phase DIN Rail 1 Module 5 (100) a Kwh-Meter
FAQ
Q1:
No light for the consumption indicator?
A:Check switch or circuit-breaker and fuse or thermal cut-off.
A2:Reinstall terminal screws on the 1 and 4. Make sure all screws are fixed. Than there should be a 230V 50Hz AC voltage between the terminal screws on the 1 and 4 when power supply is input.
Q2: No light for the consumption indicator.
A1:Only when load is running, this LED will flash.
A2;If the operating power is too low, the spacing interval of flashing will take some more time, this is why it seems like LED isn't burning.
A3:Please contact your technical supporter to replace this meter.

Q3:The register can't run.
A1: Check that the power supply indicator is burning.
A2: If the operating power is too low, the spacing interval of the pulses will take some more time, this is why it seems like the meter won't count.
A3: Please contact your technical supporter to replace this meter.

Q4: No pulse output.
A: Check the external voltage source (Ui) is 5-27V DC.
A2: Check correct connecting:connect 5-27V DC to connector 20 (anode), and the signal wire (S) to connector 21 (cathode).
A3: Please contact your technical supporter to replace this meter.

Q5: Pulse output rate wrong. 
A: Please contact your technical supporter to replace this meter.

About the Supplier

This supplier has been audited by TÜV. Verify the report on the official TÜV website with ID "MIC-ASI163483". Items marked "verified" are certified.

Watch Video
Watch Video
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.
Yueqing Page Electrical Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Economy Industrial Zone, Yueqing, Wenzhou, Zhejiang, China
verified Plant Area
3300 square meters
verified Number of Employees
115
verified Registered Capital
500,000 RMB
verified Terms of Payment
LC, T/T, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time, one month, Off Season Lead Time, one month
verified Nearest Port
Ningbo Port

Our Production Capability & Technical Expertise

verified Main Products
Timer Switch, PCBA, Cam Switch, Contactor, Pushbutton Switch
verified Production Machines
Injection Machine, Mark Machine
verified OEM Service Available
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2016-02-02
Export Year
2009-05-20
verified Main Markets
South America, Europe, Africa
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

FAQ

What to do if the consumption indicator has no light?
Check the switch, circuit-breaker, fuse, or thermal cut-off. Reinstall terminal screws on terminals 1 and 4 ensuring they are fixed. Verify 230V 50Hz AC voltage exists between terminals 1 and 4 when power is input. Note that the LED only flashes when load is running; low power may increase flashing intervals.
What to do if the register cannot run?
Check if the power supply indicator is lit. If operating power is too low, pulse spacing intervals may increase, making it seem like the meter won't count. If issues persist, contact your technical supporter to replace the meter.
What to do if there is no pulse output?
Ensure the external voltage source (Ui) is 5-27V DC. Connect 5-27V DC to connector 20 (anode) and the signal wire (S) to connector 21 (cathode). If problems continue, contact your technical supporter to replace the meter.
What to do if the pulse output rate is wrong?
Please contact your technical supporter to replace this meter.
What are the nominal voltage options?
The meter supports 110V/127V/133V AC and 230/240V AC (optional).
What is the maximum rated current?
The maximum rated current (Imax) is 45A.
How long can the data be stored?
Data can be stored for more than 25 years without power.
What is the pulse output rate?
The pulse output rate is 1000/2000imp/kWh.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now